Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Semi rigid cable RG405

Status
Not open for further replies.

Julew

Member level 1
Joined
Apr 7, 2011
Messages
40
Helped
1
Reputation
2
Reaction score
1
Trophy points
1,288
Activity points
1,586
Hello,

I read that semi-rigid cable is very usefull. I bought RG402 cable but i think that it is not very manageable. Maybe the most common rigid cable is RG405?? Thanks a lot!

Julen
 

what is your freq?
we used to use RG405.
 

Hello!

It is 2.44Ghz. RG402 is too difficult to solder in pcbs...
 

RG405 can be used to 10G, or even to 15G if you don't care VSWR.
 

Below are the specs for both cables:
https://www.hongsencable.com/pdf\20154256.pdf
**broken link removed**

At 1GHz, RG402 (2.2mm) has 0.64 dB/m attenuation, when RG405 (3.58mm) has 0.37 dB/m.

As a general rule, a thicker coax cable have lower insertion loss and higher power capability than a thinner one, with the same dielectric.
Is preferable to use a thicker one because anyway semi-rigid cables are used generally in places where they don't move too much.
 