Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Water Tank Depth Sensor problem...

Status
Not open for further replies.

Houssem85

Newbie level 5
Joined
Jan 18, 2014
Messages
9
Helped
0
Reputation
0
Reaction score
0
Trophy points
1
Activity points
67
I have designed an amplification circuit for amplifying the signal received by the pressure sensor signal MPX2010DP.

Given that the output voltage must be between 0 and 3.3V and the oltage in the input is between 0 and 6mV, is that I can use this circuit?

You find this circuit in this attachment: https://obrazki.elektroda.pl/8177014400_1390049706.jpg

Thank you
 

is that I can use this circuit?
Basically yes. You'll probably want to use a single supply capable OP with lower offset voltage than LM324.

To be able to always adjust the output zero, the second OP stage must have > 1 gain. I also think that you should use well calculated fixed instead of variable gain with a calibrated pressure sensor.
 
You have not described how that sensor will be physically connected in the tank. Remember that it is a differential pressure gauge. I believe P1 must be > than P2. Presumably, P2 will be connected to a known pressure, such as the atmosphere. That may be a given in your case. If so, I apologize, but there was another post in the past week where that factor was not considered.

John
 
better use a pressure sensor with the "AP" suffix instead of "DP"
they are already amplified, calibrated, and the output is from 0 to 5v linear...
just my 2 cts
 