Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
rx nf
beacuse the LNA is used balance design in rx, how to calculate the system NF.Generally the Function NF=NF1+(NF2-1)/G1+(NF2-1)/G2+...;
now how to calculate NF1, G1, when LNA is balance designed.
ldmos match
hi, element115
first thank ur suggestion.i don't find its input/output imdence in datasheet, but find its referrence layout; if conjugate match, PAE and efficency is best, general way is loadpull in design PA.
whether can i get ur referrence, could u send me ur schematic ...
ldmos pa
Using Philips BLF1820-90 to design 1.9G 30W PA, download datasheet from the philips website, but don't find simulated file. who can tell me how to match its input and output using microstrip in ads?
thanks in advance!
1. Rx and Tx is separated to different layer
2. use microstrip
3. use shielding house in Rx and TX circuit
4. Crystal line is separated by the ground plane, don't infect RF signal
5. PLL circiut is layouted to same layer with Rx circuit