Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Will the RF Shielding be grounded or open in this case?

Status
Not open for further replies.

tennythomas

Member level 2
Joined
Jul 23, 2010
Messages
48
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,286
Activity points
1,583
Will the RF shielding be grounded or open, when the WLAN + Bluetooth chip (W2CBW003) is enclosed by the RF shielding? This chip has WLAN & BT RF ports which are connected to 2.4GHz antennas through coaxial connectors.

Thanks in advance.
 

Re: RF Shielding

Any shield should be connected to a ground, but what can matter in some cases is where is located the ground point.
 
Re: RF Shielding

If the shielding forms a complete box, as in metal on all 6 walls, then it can just have a circuit floating inside of it.

If there are any cuts in the wall, especially for things like antennas/dc power lines/digital controls, then it is most effective to make sure the shield metal connects to the "ground plane" of the printed wiring board that the RF chip(s) are mounted to.
 
Re: RF Shielding

Shield Can should be grounded to provide good signal return path!
 