Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

measure of phase margin command file in hspice

Status
Not open for further replies.

mike_bihan

Full Member level 3
Joined
Mar 21, 2002
Messages
182
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,296
Activity points
1,531
hspice phase margin

I was using command to measure phase margin in hspice.

.meas ac ugain_freq when Vdb(out)=0
.meas ac phase_margin ******* from=1 to=****


The question is how to find the minimum phase from 1Hz to unite-gain frequence?
[/b]
 

hspice .meas ac .measure ac gain

You can try

.measure ac min_phase MIN vp(out) from=1 to=ugain_freq


The phase_margin is, then, min_phase-(-180):

.measure ac phase_margin = param ('180+min_phase')


regards
 
.measure ac hspice

What happens ? It fails on both measurements (min_phase and phase_margin)?

I've already used this type of measurements several times. You should check the lis file to see if there is any relevant warning.
 

phase margin measurement spice

the reason i failed is that I typed ugain_freq as ugain-freq,

so when it is being refered in other .meas commands, it is misinterpreted as 'ugain'-'freq'.

Thanks, it is ok now.
 

hspice command to measure phase margin

Hi,

For finding out the phase margin u connect a ACM(ac magnitude) of 1v to inverting or non-inverting terminal.

Thanks
 

Re: hspice command to measure phase margin

Hi,

For finding out the phase margin
.measure ac phaseM find vp(out) when v(out)=1

Regards
 