Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by muthukumar_ece2004

  1. M

    What happened if Multi-master and Single-master devices are connected with a I2C Bus?

    Yes Multi/Single master description is not available in the datasheet. But i got those information from TI Community forum in which we have posed as a query. Battery Pack will lost arbitration if the Processor (Mulit-master) tries to communicate with the charger IC. But anyway good...
  2. M

    What happened if Multi-master and Single-master devices are connected with a I2C Bus?

    Following are the information given in the datasheet "COMMUNICATIONS The bq20z75-V180 uses SMBus v1.1 with Master Mode and package error checking (PEC) options per the SBS specification" I don't know how you say this will not act as a Master. Please share your view.
  3. M

    What happened if Multi-master and Single-master devices are connected with a I2C Bus?

    FVM, Gas Gauge IC part number is bq20z75-v180. Here i am attaching the datasheet for your reference.
  4. M

    What happened if Multi-master and Single-master devices are connected with a I2C Bus?

    FVM, i am not monitoring I2C Bus, monitoring Battery Pack parameters using I2C Bus.
  5. M

    What happened if Multi-master and Single-master devices are connected with a I2C Bus?

    yes FVM, we are facing deadlock problem. Once the bus behaves improperly, then the communication is failing by locking the bus by one of master or something. Thanks for the solution suggested by you. I will look in to the application note. We are using Smart Battery Pack (TI's gas gauge) which...
  6. M

    What happened if Multi-master and Single-master devices are connected with a I2C Bus?

    We could not able to predict the device which holds the line. Can you able to get the answer for your question from with the help of connection of multi and single Masters with a same bus.
  7. M

    [SOLVED] Why two Fuses (in Line and Neutral) blows simultaneously?

    AC Line Filter Board schematic is attached here. The X2 Cap value is 0.1uF and Fuses are rated to 1.6A, Choke value is 27mH/1.4A. Could you please explain the schematic on what happen while switch on, switch-off and again switch-on?
  8. M

    What happened if Multi-master and Single-master devices are connected with a I2C Bus?

    In our project, we have connected Battery Pack, Controller and Charger IC I2C lines together. This causing un-interrupted error (Data line pulled to Low). Controller is a Multi-master device, Charger IC is a slave device and Battery Pack is a Single-Master. Is this is the issue due to connection...
  9. M

    [SOLVED] Why two Fuses (in Line and Neutral) blows simultaneously?

    The X2 capacitor value is 100nF. Could you please tell me how much energy this Cap can able to store? and will it enough to blow 1.6A fuse?
  10. M

    100-240VAC to regulated 220VAC converter

    Yes, what is the application for your requirement. Simple resistor and Zener diode will give you very less power (just useful to power-up a LED). I think, you are asking for TV, or Refrigerator etc, rt?
  11. M

    [SOLVED] Why two Fuses (in Line and Neutral) blows simultaneously?

    yes, i mean during powered-off, the residual current in the choke flow in reverse direction and so the X2 Cap charged. But How it will damage the Fuse during next power-up either it will create peak spike or so? I have a doubt here, X2 Cap have enough charge after powered-off due to choke's...
  12. M

    [SOLVED] Why two Fuses (in Line and Neutral) blows simultaneously?

    Our mains circuit consists of two fuses followed by a X-Capacitor (between Line & Neutral) and Common Mode Choke. None of components shorted or fault. We are analyzing in the sense of energy storage in Capacitor and Choke. During first power-up, there is no functional issue in working of unit...
  13. M

    [SOLVED] Why two Fuses (in Line and Neutral) blows simultaneously?

    In our project, the mains circuit have two fuses in series with Line and Neutral. The Fuse rating is 1.6A and our product only consume maximum current of 0.6A@250V. We have assembled 5 products. While testing one of unit fails and we troubleshoot the problem by opening the unit. And identified...
  14. M

    how to define GBW for opamp?Is that equal to the unit gain bandwidth?

    GBW is a product of Gain and Bandwidth of the Op-Amp. You can find it in the respective Op-Amp datasheet Elecstrical Specification section. Also you can find it in the graphical view Gain Vs Frequency.
  15. M

    Audio signal generation ??

    I think, you are trying to use this computer speaker as a microphone for RF transmitter, right? You can't use directly, because it may have some electronics components between speaker and output wiring.

Part and Inventory Search

Back
Top