Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
HFSS simulates rectangular waveguide of Teflon
I simulated WR75 (a = 19.05mm, b = 9.525mm), which filled with Teflon, the length is 30mm.
The pink faces are port1 and port2 respectively.
Solutin Type:
Modal, Network Analysis
In wave Port port1 and port2:
Number of modes : 1...
Hi!
I want to simulate S-parameters for measuring Teflon by T/R method, and choose rectangular waveguide WR75 for measurement.
Then using NRW method to obtain permittivity and permeability from simulating S-parameters.
First assume TE10 is dominant mode, cutoff frequency is 7.87GHz and...
In NRW method, it need to solve below equation to decide n so that the material of permeability and permittivity can be determined.
In TEM mode, tgn, Ls and lambda_0 can be obtained, lambda_c approaches infinite.
But how to solve differential part in the brackets by program? I currently use...
Thank you! nomigoraya!
Simulating between 0~ 3 GHz. CST can give me a result, but I have tried to simulate at 0~5GHz even 17~18 GHz , the mesh is still very big( hundreads of thousands )and simulation procedure works slowly, it looks like that even 17~18 GHz is still hard to simulate. I'm not...
Hi! I referenced this video to create a coax air transmission line 2-port measurement.
https://www.youtube.com/watch?v=KfJNDlOG2nA
I designed a Ferrite ring, its outer radius is 7mm, inner radius is 3.04mm and length is 20mm,
the hollow part of ring and surface are set to PEC. The ferrite...
When I run Frequency Domain Solver with hexahedral. Simulation stopped and Message showed Materials with magnetic dispersion or magnetic conductivity in port regions are not supported. What ddoes it mean? Thanks!
Hi! I designed a ferrite bead model and choose Frequency domain solver. Frequency range are between 0 ~20 GHz. When I ran it, my computer operated slowly and crashed last. How should I set up my simulation environment so that I can obtain Results from 0~20 GHz?
Thanks for help!
I choice Frequency domain solver as solver.
Oh, I see! However I want to remove higher mode from ports so that S-parameters results don't include effect from my 2-ports measurement.
Is there other method to remove effects caused by ports?
Hi! Everyone!
After I simulated, I want to remove higher mode from ports by Exclude port mode in Post Processing,then exported S parameters. But CST appeared message:
Export S parameters data failed.
My model is APC-7 coax air transmission line, and the middle part is Teflon.