Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Why do we call a 50 ohm microstrip line?

Status
Not open for further replies.

Hanh Le

Member level 2
Joined
Oct 8, 2010
Messages
44
Helped
2
Reputation
4
Reaction score
2
Trophy points
1,288
Activity points
1,531
Hello everyone,

This might be a very basic question, but I wonder why people call a 50 ohm microstrip, is it because when we use the ohm meter to measure the strip, we come up with a value of 50 ohm resistance?

Thanks
 

50 ohms corresponds to the charcteristic impedance of the transmission line.
 

If the microstip line has a characteristic impedance(Zo) of 50 ohm, then we call it as a 50 ohm transmission line. If it has Zo of 100 ohm, then it is 100 ohm transmission line.

One important thing: YOU CANNOT MEASURE THE CHARACTERISTIC IMPEDANCE USING A OHM METER. There are different methods to follow,if you want to measure the characteristic impedance.
 
yes, u characterize a trace by its characteristic impedance. yes Ohm meter is not used to measure the characteristic impedance..if u check using ohm meter its just a short.........
 