Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

where the termiinal "DN" and "SUB" conne

Status
Not open for further replies.

Depp

Member level 3
Joined
Jul 24, 2006
Messages
62
Helped
1
Reputation
2
Reaction score
0
Trophy points
1,286
Activity points
1,688
the rf mos is deep nwell process and has six terminals. where the termiinal "DN" and "SUB" connect to ?
when i connect "DN" to VDD, and "SUB" to the GND , some errors like "plus: can't handle (nil nil)" appear in the schematic editor.
how to deal with this problem?

thank you in advance.
 

Re: where the termiinal "DN" and "SUB" s

**broken link removed**

The figure above shows the deep n-well structure. In order to isolate we need
to have reversed biased junctions across substrate and deep n-well. Hence
substrate should be connected to most negative voltage and n-well to the
most positive voltage in the system.

Raduga
 

    Depp

    Points: 2
    Helpful Answer Positive Rating
Re: where the termiinal "DN" and "SUB" c

thx for ur reply, Raduga.
yes, i connected the substrate to the gnd (the most negative voltage in the circuit) and n-well to the most positive voltage. but there were error tips when i complete the simulation.
 