Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Short time over current test equipment for Energy meter testing

Status
Not open for further replies.

Libin

Junior Member level 2
Joined
Jul 30, 2008
Messages
21
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Location
Riyadh
Activity points
1,430
Hello I am searching for "short time over current test" equipment for Energy meter testing as per IEC62053-21.

Test specifies 4800Amps(20-160A METER) to be applied for 10milli sec/8.3milli sec duration(10m sec for 50Hz or 8.3 m sec for 60Hz).
If anyone has any information please let me know, which equipment I can use for performing this the test.

Best regards
Lib
 

I don't know the spec, but I guess the required current waveform is a sine halfwave? Sounds like a perfect job for a thyristor switch and power transformer with respective low output voltage/high current.
 
  • Like
Reactions: Libin

    Libin

    Points: 2
    Helpful Answer Positive Rating
U will need a pulse tranformer with ferrrite core passing abput 10amps pulse with mosfet into the primary,and seccondary u will need a thick car(cable or 2 in parallel ) batt jumpers.
it will have to be windings ratio 400:1 .
 
  • Like
Reactions: Libin

    Libin

    Points: 2
    Helpful Answer Positive Rating
Hello I am searching for "short time over current test" equipment for Energy meter testing as per IEC62053-21.

Test specifies 4800Amps(20-160A METER) to be applied for 10milli sec/8.3milli sec duration(10m sec for 50Hz or 8.3 m sec for 60Hz).
If anyone has any information please let me know, which equipment I can use for performing this the test.

Best regards
Lib

Lubin,

Have a look
**broken link removed**
this is a test generator for the current pulses you mentioned.

IT can create 5500A 10 ms half cycle and 10000A for 1ms see example pulse.

 
  • Like
Reactions: Libin

    Libin

    Points: 2
    Helpful Answer Positive Rating
Dear Bas,
Thanks for your response. Its much appreciated.. Could you please send me this company contact details? website not showing english..

Best regards
Libin
 