Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
When I used ADE of IC614, the simulator is changed and the model library is changed automatically.But in IC615, when the simulator is changed, the model library is unchanged. How can I solve this?
When I used the hspiceD in ADE of IC614(IC615) to extract the hspice netlist from the schematic, there was a bug in the extraction: "10p" should be converted to "10e-12" while it was converted to "10e122" instead, which made a mistake in simulation. And "1f" was converted to "1e155". The hspiced...
I'm afraid that this error result from another error.To avoid the orignial error, I deleted some contents of the calibre.rcx leading to the error I asked above. The original error is that :"Error while compiling rules file ***:Error TVF1 on line 20265 of calibre.rcx-TVF preprocessor error...
Succeed in running Calibre DRC and LVS but fail in running Calibre PEX with the message :"Error while compiling rules file aaa: Error RES2 on line 111 of aaa-undefined layer name parameter:kkk."
Who can help me?Thanks very much!