Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by shashidhar1990

  1. S

    sim900 stopped responding when i sent at command "AT+CSCLK"

    HI, i sent at command "AT+CSCLK" through hyper terminal and responded as ok. after that the sim900 is not at all responding to any of the commands. what is the problem with at+csclk" command . i dont know what this command does actually. please reply me . i need help .
  2. S

    getting sim900 from power down mode to ower mode

    hi, i have gsm sim900 module. when i connect adapter to it it will come into power down mode by default ,when i press the power button provided over gsm module it will come into ready state . without pressing this button is there any AT command to get module into ready mode.
  3. S

    [SOLVED] sim900 problem with receiving sms.

    hi , i solved the problem . the problem was my mobile sms settings(text messages ) input mode was in unicode mode. i changed it to gsm aplhabet/automatic it works fine now. the problem was not with gsm module .
  4. S

    [SOLVED] sim900 problem with receiving sms.

    hi , actually the code works fine with sim300. but problem is with only sim800. at+cmgf=1 command i have sent to module from microcontroller got ok response from the module but still same problem is there.
  5. S

    [SOLVED] sim900 problem with receiving sms.

    i would like to know what is the command to Read the GSM SIM 800 module settings . I would like to confirm the command i gave to set the module to Text Mode has been saved . are there any other settings (initialization ) related to PDU mode as the Messages being Sent from the same GSM are...
  6. S

    [SOLVED] sim900 problem with receiving sms.

    i gave all commands to gsm that you told ,still it is receiving as hexadecimal format.
  7. S

    [SOLVED] sim900 problem with receiving sms.

    what is #1? i did not get this?
  8. S

    [SOLVED] sim900 problem with receiving sms.

    but the thing is when i send sms by sim800 sms goes properly . this problem exists only when receiving sms .
  9. S

    [SOLVED] sim900 problem with receiving sms.

    hi i am sending the sms to the sim800 module but it is reading it in hexadecimal format. so my controller is not understand what am i sending. so please tell me how to overcome this problem. the response from sim800 when i send sms comes as fallow in hyperteminal. +cmt:"number", "" ...
  10. S

    [SOLVED] Unable to Send Multiple Messages using SIM 800 /900 .

    the same code was working fine with sim300 module. error is as fallows: at+cmgs="xxxxxxxxxxx" error "message" at+cmgs="xxxxxxxxxxx" error "message" - - - Updated - - - thank you . i solved the by introducing 2 seconds delay between "message string" and ctrl z to give time to module to...
  11. S

    [SOLVED] Unable to Send Multiple Messages using SIM 800 /900 .

    thank you. how to check for modem busy or free? should i include delay after every command i send ?
  12. S

    Unable to Send Multiple Messages using SIM 800 /900 .

    hi SIM 800 while sending the sms of size 120 characters get error response when recipients. are more than 5. I have provided delay of 1 Second between 2 messages. i am using 19200 buad rate , 8-N-1 frame format. sending single messages works well. what is the standard...
  13. S

    [SOLVED] Unable to Send Multiple Messages using SIM 800 /900 .

    hi SIM 800 while sending the sms of size 120 characters get error response when recipients. are more than 5. I have provided delay of 1 Second between 2 messages. i am using 19200 buad rate , 8-N-1 frame format. sending single messages works well. what is the standard delay to be...
  14. S

    [AVR] interfacing two wire detectors to micrcontroller panel

    hi everybody on the forum,,,,please help me now we are using 4 wire sensors/detectors interfacing to the panel where four wires consists of 12vdc, gnd ,alarmin and alarm out, where alarm out is connected to atmega microcntroller's port pins where it reads any signal change. now we are planning...
  15. S

    [AVR] error in proteus design suite

    hi , when i am loading the hex file into the proteus for atmega32 , i am getting an error like '''invalid opcode 0xFFFF at PC = 0x7002''' please anybody help me to solve this error... thanks