Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
I have further investigated this point.
I have removed the baluns in orther to check if the problem is generated by them.
So, I have performed full 2 port calibration using two BNCs with crocodile connectors and 50ohm reference resistance.
Then I have looked at the first frequency point where...
I have tried to perform the measure without using baluns on bot ports, and the result for L and C are the same.
What do you mean for "impedance matching network is not calibrated " ?
I have performed a 2-port cal (reflection and transmission) (open short load and thru)
Are you suggesting me to...
i have this option;-)
- - - Updated - - -
mmmmm
are you sure that using S parameters as i have used, implies a lossless transmission line ? it is the same way as matlab use it in s2rlgc function
- - - Updated - - -
yes i know, consider the measure upper limit at 1MHz. 10MHz measure is just...
I am measuring using 2-port network with a full two port calibration (short, open, load on both ports and thru).
A balun 50ohm -> 100ohm is connected to each port and the to the cable.
The calibration is performed with the baluns attached to the instrument
I have set systemZ0 to 100ohm, but i...
Hello,
I have a problem with inductance and capacitance measure of a transmission line 4 Kilometers long.
The attenuation and characteristic impedance are good, but L and C suddenly fall down and start oscillate.
In order to calculate RLGC model I have exported s-parameters touchstone file from...