Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by ee1

  1. E

    ILM in Encounter - N/A in timeDesign report

    Hi, I am running Encounter with ILM blocks. i have succesfully created the ILM and imported them to my top level. However, after placement step ends, and i run timeDesign, i am getting "N/A" for all values in timeDesign summary table. the sdc file is well defined and succesfully loaded at the...
  2. E

    Encounter - working with ILM

    Thanks! it works! BTW, i don't have all 3 subdirs of ILM, i have only ilm_data (i create it post route) - make sense? and regarding the definitions in env.cong : in addition to "rda_Input(ui_ilmdir)" i have there rda_Input(ui_ilmlist) and rda_Input(ui_ilmspef), should i define these as well?
  3. E

    Power supply - macro & top level

    It is above 65nm . But if i create the power ring as drawn in the picture it won't be a problem? just call the power nets with the same globalNetConnect name will be enough?
  4. E

    Power supply - macro & top level

    Hi yadavvlsi, thanks for your answers. I will create the power nets with the same globalNetConnect name or the macro and top level power nets. regarding the picture i uploded - is this the way of doing this? does it mean i can't flip my macro in top level ?
  5. E

    Power supply - macro & top level

    this is what you meant? if so, how do i make top level "see" the macro power ring? i need to do somthing in macro level?
  6. E

    Power supply - macro & top level

    Hi, my question was regarding the implementation. suppose i want to connect the hard macro in my top level without power ring aroung my macro, the way of doing this will be creating power strap in macro cell till one metal lower than the top layer? and than connect the top layer power staps on...
  7. E

    Power supply - macro & top level

    Hi, How should i connect my macro to power supply in top level? should i create a power ring for the block in block level? or just power strips will be enough? I am working with Encounter. Thanks!
  8. E

    Encounter - Create terminal

    i am using Encounter Hierarchical flow with ILM, i am having some trouble with Power Grid. which approach should i take? should i create PG in ILM till one metal lower than top metal and connect top metal PG in top level? if this is a good way to do it, should i create a terminal in ILM level...
  9. E

    Encounter - working with ILM

    Hi guys, I am trying to work with ILM in my top level, using cadence flow (i am not working in MCMM mode): in my block level i do: createInterfaceLogic -hold -dir ../outputs/my_block.ILM the ILM created succesfully. Than in top level, i write: specifyIlm -cell my_block -dir <block...
  10. E

    Partitioninng with Encounter

    Hi, I am trying to run the partition flow using Encounter. if i have an hierrarchy mutiple times, can i use the partition flow? or is it just for one hierarchy? thanks!
  11. E

    Hierarchical flow methodology

    Thanks for your reply! very good articels. If someone has a dedicated flow/commands for ecnounter - it will be great! (or i just need to extract LEF+LIB from my block and read it into my top level?)
  12. E

    Hierarchical flow methodology

    Hi, I am looking for a good reference flow manual for hierarchical place and route flow using encounter. Thanks!
  13. E

    Cadence Encounter labs?

    Do you know if i can download the labs from cadence offficial website?