Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Hello Klaus,
I have not mentioned the power supplies in op-amps otherwise +/-12V is provided.
100uF op-amp is not connected direct to op-amp. The output of op-amp is given to ADC module.
1V reference IC is used for voltage shifting from (0V to 5V) range to (-1V to +1V) using voltage divider...
This is a circuit of cyclic voltammetry in which all three electrode i.e. WE (Working Electrode), CE(Counter Electrode) & RE (Reference Electrode) are dipped in electrolyte solution.
The source voltage is -1V to +1V (mentioned in circuit) but generally we are using -0.2V to +0.6V as scanning...