Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by dasarathan

  1. D

    [SOLVED] ccs c complier int32 to float problem

    Re: ccs c complier int32 to float problem "solved " Dear Team Thanks for the support it is working fine
  2. D

    [SOLVED] ccs c complier int32 to float problem

    i think the big and little indian format is not the issue because i'm setting the int32 value in the code it self for the testing for that also im getting the same
  3. D

    [SOLVED] ccs c complier int32 to float problem

    the hex value for the modbus data is 0x 43 5d 85 73 the data received in modbus is bytes of data only we have to type cast the the four byte of data to float 32 im communicating with the l&t multifun meter WL4400 for the parameter like voltage current pf energy for the display purpose
  4. D

    [SOLVED] ccs c complier int32 to float problem

    hi guys im using ccs c complier PCH 16 bit im reading the float data from modbus rtu as the array of byte and i convert the bytes to int32 while im type casting the int32 to float the result is 0.00 float ModbusGetdata(int8 in_ValueReg) { int8 Readcount = 0; int8 ReadBuffer[15] = {0}...
  5. D

    Problem int32 over flow

    the above code is used for the ac current measurement on hall effect sensor acs712/20A
  6. D

    fram FM24C16B adressing issue

    problem solved it is the confusion withe 16Kbit as 16k byte., thanks for all your support
  7. D

    Send data using hlk-rm04 module

    HI kindly update the steps how u solved the problem.. b'coz im having one facing the problem in wifi client to my wifi adsl modem is not working ..
  8. D

    Current transformer interfacing with microcontroller

    U have to find the rms value of the signal increase the sampling to 250 to 300 time for 100ms sampler one reading multiply the obtained result and square root the mean value to get rms value
  9. D

    how to display float number to lcd

    i guys i refered mazdi book of embedded system .. i need the asm coding for the floating operation........... in c it working fine . but problem is it occupies more memory size while using sprintf fun......
  10. D

    how to display float number to lcd

    using sprintf function in keil is giving the awesome out put thank...... for ur help man .......... can u help with asm coding ha?