Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Help about calibre PEX errors

Status
Not open for further replies.

cetianwang

Newbie level 4
Joined
Nov 15, 2010
Messages
7
Helped
1
Reputation
2
Reaction score
1
Trophy points
1,283
Activity points
1,316
I have pass DRC and LVS. When running PEX, I got errors like: unable to open "svdb/***.pdb".:?::?::?: Could anyone give me a hand!
 
Last edited:

Hi,

SVDB is a database file getting generated after you run LVS. Which contains the LVS errors and other run details.

There can be two reasons because of that you are getting this error.

1. SVDB path is Incorrect : Verify the path correctly. Make sure the database file generated from your earlier LVS run exist in the LVS run directory. and Point to that location.

2. LVS is not done with RC Extraction Enabled : You need to run LVS with RC_Extraction enabled in LVS Runset. You can check some #define variable that enables RC_Extraction. and set it to true(1).