Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

How to adjust transient step in HSIM?

Status
Not open for further replies.

020170

Full Member level 4
Joined
Jan 31, 2005
Messages
231
Helped
3
Reputation
6
Reaction score
1
Trophy points
1,298
Activity points
2,221
hsimtaumax

I use HSIM.

In transient simulation, I don't know How to adjust transient step.

Default transient simulation is weird. transient step time is not uniform.

sometimes step time is large, sometimes small.

How can I set transient step point become uniform?

thanks
 

SPICE simulators adjust the time-step dynamically, in order to yield the best precision with the lowest simulation time. So you will have a smaller time-step when the signals are changing fast, and larger time-steps when things have settled.

A uniform time step would either result in poor accuracy (in case of large time-steps) or in long simulation time (in case of small time-steps).

What you usually define is the MAXIMUM time step, i.e. the time-step is adjusted dynamically, but is never larger than the value you indicate. If I'm not mistaken, HSIM this is done using the HSIMTAUMAX parameter.

Regards.
 

    020170

    Points: 2
    Helpful Answer Positive Rating
Status
Not open for further replies.

Similar threads

Part and Inventory Search

Welcome to EDABoard.com

Sponsor

Back
Top