Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

[SOLVED] Need explanation about specific part of SDF file

Status
Not open for further replies.

ebrahimi.khoy

Member level 3
Joined
Dec 4, 2010
Messages
64
Helped
2
Reputation
4
Reaction score
2
Trophy points
1,288
Activity points
1,736
I am writing a simple SDF parser. In some rare cases I have one timing specifications instead of two. What is the reason?
Example:
Normal case: (IOPATH A1 ZN (0.061:0.062:0.062) (0.056:0.057:0.057))
Strange case: (IOPATH A2 ZN (0.064:0.065:0.065))
 

Hello ,

Pl go through the attached document.(specifically page no : 45,46)
 

Attachments

  • SDF Annotator Guide.pdf
    804.7 KB · Views: 1,257
According to this document it means that both rise and fall transitions have same value.