Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by Quantum Flux

  1. Q

    Pre-conditioning analog signal for adc

    I hadn't noticed the log scale, just the line. I see now that it is logarithmic. Also I was confused between the graph showing hundreds of mV and the table showing 30-50mV. I have sort of worked out a solution for the design now. The problem was the simulator on my iPad was wrong. I've modelled...
  2. Q

    Pre-conditioning analog signal for adc

    The sensor is supplied with 6VDC for a heating element. The CO2 reaction causes a differential of between 0-50mV on another set of terminals. This must be fed through a buffer amp with at least 100G input impedance. The thing is, the 0-30mV range is meaningless. Only 30-50mV is useful data. So I...
  3. Q

    [SOLVED] SAW filter identify. Marking is "I 5A"

    You're welcome. It's part of my job so I have some practice at finding these.
  4. Q

    Pre-conditioning analog signal for adc

    Yes that will get my signal up to power, but I'm not sure the best way to trim out the 0-30mV range as it is wasted signal resolution. I need to get a 30-50mV signal moved to 0-20mV.
  5. Q

    Pre-conditioning analog signal for adc

    I have been given a project for which I must use an ADC and other things. The ADC accepts 0-3VDC. I have decided a co2 sensor will supply my analog signal. It needs 6v for a heating element and it supplies a signal of the range 30-50mV depending on c02 level. This must go through a buffer amp...