Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by nikator

  1. N

    I have problem with PCB print

    this is my project print preview - - - Updated - - - i have problem with pcb print. i work on project suddenly my lap top turn off (its battery is finished). after i turn on laptop and go to altium i see that my project is disturb. but i open it from history that work on it. but when i want to...
  2. N

    calibration tgs2442 co detector sensor

    yes it was clear. tanks for aim
  3. N

    calibration tgs2442 co detector sensor

    i can't understand what you say. i have datasheet of sensor but i can't drive this sensore i attach the data sheet and the brochure for calibration this sensor: i can't find figs1 and 2 that is Mentioned in page 2 of brochure:bang:
  4. N

    calibration tgs2442 co detector sensor

    hi i want to calibrate tgs2442. any one can help me?
  5. N

    sim900 module problem

    HI I want to connect it to PC . i use MAX232. but i can't see any text in Hyperterminal screen. i thinck my module is'n turn on because when i call to it oprator say "your set is turn off" when i turn module my sim VDD voltage is 1.83v i can connect module to pc but can not send sms. i rescive...
  6. N

    sim900 module problem

    hi i use sim900 module. u can see it's Schematic in this: https://www.open-electronics.org/small-breakout-for-sim900-gsm-module/ but wen i turn on this module it's NETLIGHT be turn and blink but when i call it say " the cell phone is turn off" i want use only sms can any one help me?:sad:
  7. N

    datasheet of sim300cz-v3.04

    I send Email for all of the SIMCOM company vendor but I don't receive answer.
  8. N

    datasheet of sim300cz-v3.04

    hi I turn on my module with sim300cz-hd-v1.01 . I think my module has same pinout. when I push the PWRKEY and connect to GND my NETLIGHT led turn on and start to Blink. but I don't receive any data in HyperTerminal. I check pin voltage, voltage of SIM VDD is 0.what you think? what's the...
  9. N

    datasheet of sim300cz-v3.04

    hi tanks for attention. I check that document but it isn't useful for me . I want sim300cz-v3.04 datasheet .it is important to Note to this Phrase "cz-v3.04".
  10. N

    datasheet of sim300cz-v3.04

    hi I want to send message with PC . I buy sim300cz-v3.04 module to send and receive sms from PC. I can find the Schematic for it. and find datasheet of SIM300CZ_HD_V1.01 datasheet. I connect it pin According to this datasheet . but I can't use it , it has not any out put. I check voltage of pin...
  11. N

    datasheet of sim300cz-v3.04

    when i use above datasheet my sim vcc to be 0 volt.why it's happen?
  12. N

    help for gps module???

    hi tanks for assistance i can see the reasonable output. but i my module can not detect my Latitude and Longitude. it shown the true time but can not detect true Latitude and Longitude
  13. N

    help for gps module???

    i check baud rate in the module datasheet write " it's baud rate is 9600 " and i select 9600 baud rate for hyper terminal. but i see the Unclear shape like Delta shape
  14. N

    help for gps module???

    hi i have gps module (GMS6-cr6). i conecte its vdd ang ground wire. and then i conect it's RS232 port to PC. and run Hyper terminal program but i cant see true data .i see the below image. can you help me?
  15. N

    datasheet of sim300cz-v3.04

    hi I use this datasheet but before and after I turn the module, voltage on sim card VCC port is low .