Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
good afternoon,thanks for u kindnes,please help me for add syntax quantifying (sum),i have syntax for control 2counter,i want 2 counter can be quantifying(sum) for Total value,for example display in Lcd 16X2 :
digit value in counter0 is 10 and digit value in counter1 is 10,picture :
i need...
Dear
All my master
i have project with ping sensor this source code for control distance (Jarak) in indonesia language
'-----------------------------------------------
'
' CHIP : ATMEGA8535
' CLOCK : 16 MHZ
' LCD : PORTC
' SIG SENSOR : PORTA.1
'------------------------------------------------...
this aplication is college homework,i still not yet understand because i have just learnt programming,ok i'll try first and modify ,thaks a lot for master ArchZone and master doraemon
Dear all
i have a problem with my project RUNNING HOUR +TIMER CONTROLL
the problem is digit second in digital running hour is to late,not in one second
in this project i'm use software AvrOspII
this my source code
'----------------------------------
' Running Hour
'
' OUTPUT : LCD 2X16...
dear
All
i need your help ,i have a timer project and counter,i want to if power switch off and then on,timer is continu counting not counting in a new begin,example :
last power switch off timer in position 3 sec,after power switch on timer is continu counting 4sec,not start in begine 0 sec...
Your RIGHT SIR,this is the final source code :
$regfile = "attiny2313.dat"
$crystal = 11059200 'this value 0% nothing efect for a timer
Dim X As Byte
Ddrb = &B11111111 'output
Ddrd = &B00000000 'input
Portd =...
It still doesn't work,this fungtion :
in start portb is direct active,not waiting 3sec,and then if i press pind.5 times portb is direct off,not count after 7times
Yes,don't have second switch
ok i'll try,thks
- - - Updated - - -
sory sir it doesn't work,this code fungtion only for active portd,just that,
i need in the first time power on,portb is inactive until 3 second,and then active
an then when pind.5 is counting 7 times then portb is inactive...
dear all my friend
i have a sample source code in BASCOM,this fungtion only for on/off
$regfile = "attiny2313.dat"
$crystal = 1000000
Ddrb = &B11111111 'output
Ddrd = &B00000000 'input
Portd = &B11111111 'pull up
Do
If Pind.5 = 0 Then
Portb = &B11111111
End...
dear all
please help me,i have a trouble with my machine,the power suplly is destroy:cry:.
can't you hlep me schematic power supply input 220VAC to output 160VDC,2Ampere(out put can be adjust with potentiometer range 0-160VDC)
thanks alot for you attention
your souce code is work 100% all i need:razz:,after i modify Portd after code Dim Time_on As Word
thanks alot sir,by the way don't be borring to help me next:lol:
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.