Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
3 phase inverter
Hello
I've seen that some 3 phase bridge topologies use three extra diodes in serires in the branch. This topology is shown in the image bellow.
For a BLDC motor drive, will this topology help to handle back EMF?
will this make a more robust brige?
what other considerations...
igbt dc bus inverter
Hi Again.
I'm checking some measurments I took today, from the IGBT inverter bridge. The tests where made at a 50Vdc bus voltage. With the motor as inductive load. The dead time is 8us, automatically generated by the PWM module on the dsPIC.
The Image "print_11" are the...
bldc hall sensor timing advance circuit
Hi Again
I'm posting the signals of the final PWM scheme. I hope I've understanded right this time.
mananshah:
Well before doing a drive you need to kwon the target motor. It's true that the 3phase bridge topology is the same for Induction, synchronous...
igbt dead time
Hi mananshah
I'm attaching a document that has many formulas for snubber circuit calculation.
About PWM sequence I was using the sequence found in all microchip application notes. No I've changed thanks to FvM, this PWM scheme gives you a better torque at low speeds. I'm using...
burning test for igbt modules
Thanks FvM.
I've made the change in the PWM scheme. Now my position PI works fine, I need some time to adjust Gains, and add an acceleration ramp. Thanks once again.
I thought the PWM scheme I was using was usefull, because I saw it in almost al the BLDC app...
ir2210 driver burning
Thanks FvM.
I'm getting confused here with the control signals. The next image shows what control signals Im sending to the inverter bridge.
Active: means a solid 15v to the lower IGBT gate.
PWM: a 10Khz with a max 75% duty to high IGBT.
off: the IGBT should be an...
igbt inverter bridge images
Hi Again
The capacitors solved the rising voltage problems in the DC voltage bus.
I attempted to the controller (postion PI with velocity PI in cascade), but I had many problems with the bootstrap capacitors getting discharged.
So I had changed the PWM scheme...
Re: Simulation Software
Hi
A teacher recomended me the LT spice. He told me that it includes the ir2110 for simulation. You can download it by registering. You coun found the link by searching in google.
Hope this helps.
Alex
Hi
I will recomend you these app notes, they cover the basics of BLDC:
https://ww1.microchip.com/downloads/en/AppNotes/00857a.pdf
https://ww1.microchip.com/downloads/en/AppNotes/00885a.pdf
It will also help to know:
what is the motor voltage rating?
what do you want to move (application)...
low speed bldc motor
Hi Nandulal
I'm also developing a 3phase BLDC drive 300v 5 amp, still testing it at 180v, using a dsPIC30F3011. I have the vibration problem when moving the motor at low speed. I think this is named cogging. It is caused by torque ripple during pole changes. Also static...
why my dc motor can not start?
Hi gsecer
Well the voltage rise, were spikes of of 160v, measured with a oscilloscope. A multimeter won't meausre this kind of spikes. You don't loss anything by adding the bus capacitor, give it a try.
Alex
24v bldc driver
Hi gsecer
I think I was in this situation last week.
Try Adding a 4700uF(50v or +) capacitor parallel to your 24v DC bus. This may solve your problem.
What is happening here is, that the current circulating through the motor inductance is being converted to voltage because...
bldc 100% duty cycle bootstrap
Hi gsecer
I'm also developing a BLDC drive using the IR2110.
check:
I've posted my shcematic and many wave forms.
I started by experimenting with a small 24v BLDC motor. At some moment I had the same problem you describe "Dc motor does not rotate without...
dead time inverter igbt
Thanks GetDeviceInfo.
I think my problem was that I did not have bus capacitors. I added two 820uF (1.6mF total) capacitor to the DC BUS, and the voltage spikes and rising stopped. The measurements I used to get to this conclusion are in the following images.
The test...
igbt switch scheme in three phase inverter
Hi FVM
I have only two little bus capacitors. One 0.1uF at the output of the power supply, then a couple of 14 gauge 15cm long cables go to the inverter board, where another 0.1uF capacitor is placed between the bus terminals.
Do I need to put more...