Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Errors in generating netlist in Cadence Capture CIS -> Allegro, what to do?

Status
Not open for further replies.

clupus

Newbie level 4
Joined
Aug 1, 2012
Messages
6
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,346
Errors in generating netlist in Cadence Capture CIS -> Allegro, what to do?

Hello to everyone,

I am new to the Cadence OrCAD Capture CIS and Allegro suite. Now I need to create a pcb with those tools. When I activate the generation of the netlist I get the following errors/warnings:
Code:
********************************************************************************
*
* Netlisting the design 
*
********************************************************************************
Design Name:
Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\signal_aufnehmer.dsn
Netlist Directory:
Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro
Configuration File:
C:\Cadence\PSD_15.1\tools\capture\allegro.cfg

Spawning... "C:\Cadence\PSD_15.1\tools\capture\pstswp.exe" -pst -d "Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\signal_aufnehmer.dsn" -n "Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro" -c "C:\Cadence\PSD_15.1\tools\capture\allegro.cfg" -v 3 -j "PCB Footprint"
#1 Warning [ALG0016] Part Name "C_SMD_1206_1206_CAP_REFLOW_10P_1206_1206_CAP_WAVE" is renamed to "C_SMD_1206_1206_CAP_REFLOW_10P_".
#2 Warning [ALG0016] Part Name "ELCAP_10UF_50V_CAP_ELCAP_50_110_RM20_10UF" is renamed to "ELCAP_10UF_50V_CAP_ELCAP_50_110".
#3 Warning [ALG0016] Part Name "C_SMD_1206_1206_CAP_REFLOW_C_SMD_1206_1206_CAP_WAVE" is renamed to "C_SMD_1206_1206_CAP_REFLOW_C_SM".
#4 Warning [ALG0016] Part Name "RJ45_8P_PCB_A_FEM_CONN_RJ45_8P_PCB_A_FEM_RJ45-8" is renamed to "RJ45_8P_PCB_A_FEM_CONN_RJ45_8P_".
#5 Warning [ALG0016] Part Name "PCB_1X02_CONN_PCB_1_2_S_GMR_6_CONN_PCB_1_2_A_M, CONN_PCB_1_2_A_F" is renamed to "PCB_1X02_CONN_PCB_1_2_S_GMR_6_C".
#6 Warning [ALG0016] Part Name "PCB_1X02_CONN_PCB_1_2_S_GMR_7_CONN_PCB_1_2_A_M, CONN_PCB_1_2_A_F" is renamed to "PCB_1X02_CONN_PCB_1_2_S_GMR_7_C".
#7 Warning [ALG0016] Part Name "PCB_1X02_CONN_PCB_1_2_S_GMR_8_CONN_PCB_1_2_A_M, CONN_PCB_1_2_A_F" is renamed to "PCB_1X02_CONN_PCB_1_2_S_GMR_8_C".
#8 Warning [ALG0016] Part Name "PCB_1X03_CONN_PCB_1_3_S_
PCB_1X03_CONN_PCB_1_3_A_M, CONN_PCB_1_3_A_F" is renamed to "PCB_1X03_CONN_PCB_1_3_S_PCB_1X0".
#9 Warning [ALG0016] Part Name "PCB_1X02_CONN_PCB_1_2_S_GMR_1_CONN_PCB_1_2_A_M, CONN_PCB_1_2_A_F" is renamed to "PCB_1X02_CONN_PCB_1_2_S_GMR_1_C".
#10 Warning [ALG0016] Part Name "PCB_1X02_CONN_PCB_1_2_S_GMR_2_CONN_PCB_1_2_A_M, CONN_PCB_1_2_A_F" is renamed to "PCB_1X02_CONN_PCB_1_2_S_GMR_2_C".
#11 Warning [ALG0016] Part Name "PCB_1X02_CONN_PCB_1_2_S_GMR_3_CONN_PCB_1_2_A_M, CONN_PCB_1_2_A_F" is renamed to "PCB_1X02_CONN_PCB_1_2_S_GMR_3_C".
#12 Warning [ALG0016] Part Name "PCB_1X02_CONN_PCB_1_2_S_GMR_5_CONN_PCB_1_2_A_M, CONN_PCB_1_2_A_F" is renamed to "PCB_1X02_CONN_PCB_1_2_S_GMR_5_C".
#13 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_820R_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_820R".
#14 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_4,7K_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_4,7K".
#15 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_0R_S
MD_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_0R_S".
#16 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_1K_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_1K_1".
#17 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_3,9K_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_3,9K".
#18 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_220R_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_220R".
#19 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_27R_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_27R_".
#20 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_680R_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_680R".
#21 Warning [ALG0016] Part Name "R_SMD_1206_1206_RES_REFLOW_680_1206_1206_RES_WAVE" is renamed to "R_SMD_1206_1206_RES_REFLOW_680_".
#22 Warning [ALG0016] Part Name "INA128_DIP8_3_OBL_INA128_SOIC8_REFLOW" is renamed to "INA128_DIP8_3_OBL_INA128_SOIC8_".
#23 Warning [ALG0016] Part N
ame "TLV3502/SO8_SOIC8_REFLOW_TLV3502" is renamed to "TLV3502/SO8_SOIC8_REFLOW_TLV350".
Scanning netlist files ...
Loading... Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro/pstchip.dat
Loading... Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro/pstchip.dat
Loading... Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro/pstxprt.dat
Loading... Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro/pstxnet.dat
Error: Line 15 in file Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro/pstxnet.dat:
	  Reference designators inconsistent in xprt and xnet files  
	Detected in function: pstFindInstByOldPathName 
Error: Line 15 in file Y:\USER\S-WOLFC\SA\BOARDS\FPGA_INTERFACE\Signal_Aufnehmer\allegro/pstxnet.dat:
	  Error loading the net list file  
	Detected in function: ddbLoadPstXFiles 
#24 Error   [ALG0036] Unable to read logical netlist data.

I found https://www.edaboard.com/threads/33260/ where it is mentioned, that this is a problem of wrong names. They seems to be truncated and later cannot be found again (As far as I have understood).

I found the truncated names in the *.dat files, but I do not understand how to avoid the truncation. In the property editor (opening by double clicking a device) I do not find those long names mentioned in the warnings.

So my question is: What can I do to make things work?

Thanks in advance
Christian

PS: If you need futher information, please feel free to ask.

- - - Updated - - -

Hello,

after copying all sheets of the project in OrCAD Capture CIS into a bare, new project and rerunning the netlister, all went well. (A colleague told me this trick)

Now the only question is: Why does this happen? And way to avoid copying all sheets?

Thanks
Christian
 

https://www.edaboard.com/threads/33260/

go through the link it will help you

As you might have overseen: I myself found the link (mentioned in my first message) but was not able to find the problematic strings in the parameter editor. If you could tell me some more information where to look, it would be very useful. Espacially I do not know where the "component name" is located. I think it is composed of different entries in the parameters but I do not knaow if that is correct.

Thanks
Christian
 

You can open your pstxnet.dat file in som etext editor and check the line number 15 for the error.
Also you can goto the "allegro" folder which is created in the directory where sch is saved and inthat look for netrev.lst file and open it in text editor you can get some idea from it that where exactly is the error.
 

try to open pstxnet.dat file using excel and check row 15 this net has some error you can rename it or correct the Error
 

Hello,

I have the 2 errors in netlist file. Please help me and tell me what to do. Thanks.


------ Oversights/Warnings/Errors ------


ERROR: File "VD19.brd" is being edited by user "vpdo" on date "Wed Feb 11 12:45:34 2015" on system "WKS-47". Resolve lock file and re-run netrev.

#1 ERROR(SPMHNI-175): Netrev error detected.

#2 Run stopped because errors were detected

netrev run on Feb 11 12:49:27 2015
DESIGN NAME : 'QLNK-100001'
PACKAGING ON Sep 10 2012 04:46:09

COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON

2 errors detected
No oversight detected
No warning detected
----------------------------------------------------------------------------------

:bang:
 

your BRD file is locked or still being used by user "vpdo" get it unlocked then re-import the netlist.
 