    Closed: Re: Simulation Buck Converter

    a good idea to leave the diode as it is - keep things simple initially, it is fairly obvious the 1mH choke is part of the buck ckt.
  2. Closed: Re: can triacs rapidly switch AC into a transformer

    your approach is a little bit simplistic - you will need snubbers across the mosfet switch, and source referenced gate drive, you will get maximum power near the mains peaks ( 325Vpk for 230Vac...
  3. Closed: Re: can triacs rapidly switch AC into a transformer

    forced commutation was used to turn off SCR's ( mainly ) and triacs - however a lot of extra circuitry is required - then along came mosfets & IGBT's so much easier to chop the mains or...
  4. Replies
    3
    Views
    146

    Closed: Re: Simulation Buck Converter

    you can't turn an SCR off once fired - so your ckt needs a xtor or mosfet - which you can turn off

    the SCR will stay on forever once triggered ...
  5. Closed: Re: ELECTRICAL AND ELECTRONICS Instrumentation

    PMMC = permanent magnet moving coil - meter, I think all moving coil meters give an average reading... moving iron have expanded scales as they are not linear with coil current ...
  6. [SOLVED]Closed: Re: Iron sheet laminated gapped core inductor variation

    a random data sheet has no bearing on a gapped choke made using transformer steel, an old measuring device with unknown capacitor degradation - and unknown whether it properly measures phase angles...
  7. [SOLVED]Closed: Re: Iron sheet laminated gapped core inductor variation

    Barkhausen noise would not rise to the level needed to seriously interfere with measurement at 50mV, the main issue with 50mV measurement is the likely level of environmental noise, and the...
  8. Closed: Re: Does it exist an AC to AC converter in small package for converting 220v to 110v?

    the word AND in the above quote makes the sentence incorrect, you can have the first 65 degC or the last in an half cycle - but not both - for 110Vac rms from 230Vrms ...

    unless that is what...
  9. [SOLVED]Closed: Re: Iron sheet laminated gapped core inductor variation

    there is no published paper or article that says the slope or behaviour the BH curve at low excitation is any different to the slope/ behaviour at slightly higher excitation - nor can c-mitra ...
  10. [SOLVED]Closed: Re: Iron sheet laminated gapped core inductor variation

    there is no evidence to support this - I have never observed this - it also goes against the principles of physics relating to magnetic materials.
  11. Closed: Re: Does it exist an AC to AC converter in small package for converting 220v to 110v?

    Conduction angle is in fact about 65 degrees i.e. the first, or last 65 degrees of each half cycle, if you want 110V rms from 230Vrms

    - - - Updated - - -

    154387 per the above ...
  12. Closed: Re: Synchronous Buck Converter FET selection

    SMT & heat dissipation - always problematical ....
  13. Closed: Re: Half-bridge versus Full-bridge for Power Dense supplies?

    nope ... tisn't the rail splitting caps diverge quickly if you try to do current mode control and don't compensate for this ...
  14. Closed: Re: Synchronous Buck Converter FET selection

    Unless you have a 200MHz scope and high quality scope probes - you may not see the true rise and fall times - have you calibrated your probes? - via the 5V square wave on the scope

    Fet temp...
  15. Closed: Re: Synchronous Buck Converter FET selection

    Is your choke heating your fets? - it may well be that the IC is damaged and can't drive them properly - I would expect <50nS rise and fall times ...
  16. [SOLVED]Closed: Re: Iron sheet laminated gapped core inductor variation

    that is exactly what I said ...
  17. Closed: Re: Does it exist an AC to AC converter in small package for converting 220v to 110v?

    some what overkill. but:

    https://www.ebay.com/itm/Stepdown-Auto-Transformer-SD-13G-1000-VA-MAX-220-240V-TO-110-120V-Todd-Systems/401769910892?hash=item5d8b5a526c:g:cA4AAOSws3lc4YRE
  18. Replies
    29
    Views
    934

    Closed: Re: IGBT Short Circuit problem

    Dear kripacharya, your post appears to show a limited understanding - minor shoot thru is caused by transient gate rise when the other device turns on - on another matter it appears you are...
  19. Closed: Re: Half-bridge versus Full-bridge for Power Dense supplies?

    you can't easily have current mode control with HB - so if you are seeking a tight dynamic loop - FB may be the better option.
  20. Closed: Re: Does it exist an AC to AC converter in small package for converting 220v to 110v?

    an auto - Tx is half the weight approx as you likely don't need isolation - if you get one on a toroid and heatsink the two sides - this will work and be in the order of 100x100x100mm... 60Hz...
  21. [SOLVED]Closed: Re: Iron sheet laminated gapped core inductor variation

    having read the above - and, as some one who regularly designs iron cored chokes and transformers - there is a lot of mis-information in the above - the simple facts are at 50mV there is too...
  22. Closed: Re: Unsure about this current sensor for use in saturation current measuring circuit.

    tight looping of cable will no doubt affect the accuracy - if you can have large diameter looping, say 300mm then such effects will be minimised
  23. Replies
    29
    Views
    934

    Closed: Re: IGBT Short Circuit problem

    I meant for the OP to post the gate drive waveform - Swend even 10E for turn off R may be too high ..
  24. Replies
    29
    Views
    934

    Closed: Re: IGBT Short Circuit problem

    post a pic of the gate drive please ...
  25. Replies
    6
    Views
    262

    Closed: Re: Diode value in voltage doubler circuit

    those numbers look like date codes - what else is on the devices?