Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Radiated Emission from EUT

Status
Not open for further replies.

bhavanisurabhi

Newbie level 4
Joined
Dec 15, 2009
Messages
5
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Location
India
Activity points
1,326
Hi,

We have tested our equipment for CISPR 25 radiated emission limits. The emission result is attached. I have trouble shooted the problem element. There are 5 switching components in my design - microcontroller, LED driver IC, external crystal, DC-DC module for RS485, DC-DC module for LEDs. When verified in Anechoic chamber, I have localized to DC-DC module for LEDs as the component responisble for emission. remaining component are fine. I have verified for harmonics in emission graph and found 300KHz harmonics which matches its switching frequency.

I also verified by shielding the DC-DC module with Aluminium box for it. Only I have, in and out slots for cable. I have utilized shielded cable for wiring and also grounded the shield to 24V -ve (My system works on 24V DC battery in vehicle).
Emission reduced slightly but still it is crossing limits.