Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

After P&R and CTS, is it a need to set_clock_uncertainty

Status
Not open for further replies.

bradyue

Member level 2
Joined
Jan 18, 2008
Messages
47
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,286
Activity points
1,603
After P&R and CTS, is it a need to set_clock_uncertainty to do PT?
Say, if the clock skew in CTS is confined to 0.1. Is it necessary to set_clock_uncertainty to do PT analysis? To my knowledge, after the CTS is dertermined, the clock skew is a certain value. PT only needs to us worst_case for setup time calculate and best_case for hold time calculate. Or, set_clock_uncertainty just for process deration?
Please help me on this...
thany you
 

Re: After P&R and CTS, is it a need to set_clock_uncerta

Hi bradyue,

clock uncertainty = clock skew + clock jitter.

So after CTS, you still need to set clock uncertainty = clock jitter.

That mean your clock uncertainty value will be lesser without considering the clock skew value.

Hope this help.