Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

assura lvs parameter mismatch problem?

Status
Not open for further replies.

bocinverson

Newbie level 4
Joined
Apr 18, 2007
Messages
6
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,308
assura lvs parameter check

hi everybody,
when i do lvs in assura,i meet a question
parameter mismatch for instance
 

Just by seeing the names is kind of difficult to get the issue.
I see that instance names are _1, _2 ... to _5, are you using a SERIES parameter. In that case, a normal error is, when you use SERIES resistors and you want them shorted, is to short all of their heads, but the real thing is that you need to short the very first head with the very last one (all the internal heads are independent or different nodes) in order to avoid this issue you must correct the connection (or use parallel resistors)
 

    V

    Points: 2
    Helpful Answer Positive Rating
hi layout
i have resolved my problem,thank you for your help very much.
 