Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Explanation pf TMAX chain test options

Status
Not open for further replies.

diag

Member level 3
Joined
Dec 4, 2003
Messages
59
Helped
1
Reputation
2
Reaction score
0
Trophy points
1,286
Activity points
301
chain test ?

Below are TMAX chain test options , anyone know which one to be select ? and why ?

HAin_test <OFf | 0011 | 0101 | 1000 | 0111 | <string>>

OFf - Do not generate pattern.
0011 - (Default) Generate a repeating pattern of 0011...
0101 - Generate a repeating pattern of 01...
1000 - Generate a pattern of 0's lead by a 1 (that is, 10000...000)
0111 - Generate a pattern of 1's lead by a 0 (that is, 01111...111)
 

Re: chain test ?

I would imagine the various patterns are for making scan debug easier. You can tell more about the nature of the failure with different patterns.

or DFT talk/info go to:
DFT Digest
DFT Forum
 

    diag

    Points: 2
    Helpful Answer Positive Rating
chain test ?

that's right . in fact tmax dump out scan_chain test pattern by default .

TMAX generate sacn_chain test parrent only for debug if you suspect you have scan chian failed .
 

Re: chain test ?

hi,

The default from Tetramax(0011) is best. And the reason for the same is that it takes into account all the transitions.

0011

0 -> 0
0 -> 1
1 -> 1
1 -> 0