Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Cannot switch to analog simulation in Cadence

Status
Not open for further replies.

spweda

Full Member level 3
Joined
Jun 28, 2001
Messages
184
Helped
7
Reputation
14
Reaction score
2
Trophy points
1,298
Activity points
1,261
When I use icfb to open cadence, the default simulation tool is digital. If I switch thr simulation tool to analog, it stops. I use ic154.
 

In .bashrc file did you assign

CDS_Netlisting_Mode="Analog"

??
 

    spweda

    Points: 2
    Helpful Answer Positive Rating
Thanks for suggestion. I added CDS_Netlisting_Mode="Analog" in csh file. However, nothing changed. I found out that if I waited for 20 minutes, it eventually opened the simulation environment menu. It is due to Java needed by Scanwave. If I run scanwave in terminal, it opened immediately. In Cadence website, it said the bug was fixed in the ic51 USR1. I used IC5141 USR3. It is possible to set the default waveview to AWD instead of Scanwave?
 

It is possible to set the default waveview to AWD instead of Scanwave?

Session -> Option -> Waveform Tool

change to AWD

Save State

After that when you will Load State the AWD option will be autoloaded also.

Another way: after change to AWD try to save Session in CIW. But I didn't try this way for AWD, so I am not sure.
 

Which OS do you use ?? Cadence recommends RH WS 3.0 only and that's why some compatibility problems may occur..
 

I use mandriva Linux 2006 since my PC only has one SATA drive and I would like to have dual-boot Windows and Linux. For some unknown reason, I could not boot the Windows if I install the Red-Hat Enterprise 3.
 

spweda said:
I added CDS_Netlisting_Mode="Analog" in csh file.

Hi

I think if you are using csh rather than bash, then you have to omit the equal sign '=' from your .cshrc file, i.e. let it like that: CDS_Netlisting_Mode "Analog"

I hope it work then..
Best Wishes,
Ahmad,
 

Status
Not open for further replies.