Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

problems P89C664 -> P89V664

Status
Not open for further replies.

do interior

Member level 3
Joined
Feb 21, 2002
Messages
55
Helped
2
Reputation
4
Reaction score
2
Trophy points
1,288
Location
Brasil
Activity points
355
p89v664

I have a project that it functions with the P89C664 to the some time, as obsolete it this, I changed for the P89V664, but with it it does not function, he is instavel, resets… somebody ja had problems similar? Some suggestion?

Tanks!
 

p89v664 timer 0 problem

My problem is serious… nobody had problems in this exchange???
 

Have you read the migration document from NXP?
**broken link removed**


wek
 
Yes, ja had read. Aparently the V is more sensivel and demands a more careful layout, but not yet I know accurately what to make so that it functions with stability, without resets, etc…
 

From V66x Migration Kees Jansen – 2006 June 1 Technical note
* Old applications with minimum decoupling might need an update for migration to the 89V66x. In general no problem are expected. A check on waveform of the Vdd of the micro is advisable.
* The ALE pin of the 89V66x must have an update with a pullup resistor (between 3k and 50kohm) in those applications where the load capacitance is larger than 30 pF during reset. Otherwise the micro might enter a test mode.
 

I placed pullup in ALE, 10k, and pulldown in P4, and vcc the this ok…
 