Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

understanding meaning of DRC errors

Status
Not open for further replies.

nijMcnij

Full Member level 1
Joined
Dec 6, 2005
Messages
97
Helped
5
Reputation
10
Reaction score
4
Trophy points
1,288
Activity points
2,167
hello all,

i have designed and am laying out a 10 bit ADC in Virtutouso XL.

however, i am experiencing extremely difficult time with DRC verification since the error messages are very cryptic to me.....i use the find marker and explain marker commands, but still i don't understand the difference between...for e.g

figure causing multiple stamped connections and figure having multiple stamped connections.

so........where can i read about the meaning of the various DRC messages?

many thanks
 

You have two or more different connections to the substrate.

Regards
 

    nijMcnij

    Points: 2
    Helpful Answer Positive Rating
Use psub2 layer to avoid this kind of error.
 

    nijMcnij

    Points: 2
    Helpful Answer Positive Rating
You can understand the DRC errors from the design rules file.You can ask your customer for such kind of file.Every drc error with the error number is explained with figures which would help u to understand better
 

    nijMcnij

    Points: 2
    Helpful Answer Positive Rating
Hi,
If u r using hercules they provide some pdf files about these drc error explaination.Go through these pdf files.
Regards,
Pramod
 

    nijMcnij

    Points: 2
    Helpful Answer Positive Rating
see the help of your program for more information

Fire in the Wire :idea:
 

    nijMcnij

    Points: 2
    Helpful Answer Positive Rating
Hallo

Check all ur NSUBSTRATE CONTACT are Connected / PSUBSTRAT r connected
 

    nijMcnij

    Points: 2
    Helpful Answer Positive Rating
thank you all for your comments,

i know that the solution to this particular problem is the substrate contacts, but i want to be able to read about other potential errors......i am using cadence virtuouso XL 5.0.33.......i checked the divaDRC.rul file...no numbers there


???????
 

you can not find this error number in divaDRC.rul.
In geomConnect() section or through geomStamp() command ,the connectivity
is defined.
Diva will check layer's connectivity internally.
 

    nijMcnij

    Points: 2
    Helpful Answer Positive Rating
I think you should look for the commands in divaReference,and you will understand the means.
 

Status
Not open for further replies.

Part and Inventory Search

Welcome to EDABoard.com

Sponsor

Back
Top