Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

synchronous motor problem

Status
Not open for further replies.

eng.saeed

Newbie level 6
Joined
Mar 28, 2006
Messages
13
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,387
Hi everybody....

I have a problem that I could not solve, and really need a help...

It says:

In a factory, the following are the loads:

Induction motors: 1000 hp
0.7 average power factor
0.85 average efficiency

Lighting and heating load: 100 KW

A 3Φ synchronous motor is installed to provide 300 hp to a new process. The synchronous motor operates at 92% efficiency. Determine the KVA rating of the synchronous motor if the overall factory power factor is to be raised to 0.95.
Determine the power factor of the synchronous motor..



Thanx a lot
 

Hi madeza....

thanx for your consern....

This is the only information, and based on the provided information, the problem should be solved...



Thanx...
 

It seems that it is a tough question to be solved....

any way.... thanx for passing by.....
 

Hi Eng.saeed,

Haven’t done this type of calc for years but I’d approach it like this:

Convert everything from HP to KW

Use the efficiency figures to calculate the actual power drawn in each case

Draw a triangle showing the original KW, KVA, KVARS PF (you have power and PF so you calculate the KVARs and KVA). i.e. before the new motor is attached


Draw another triangle showing the same but including the new motor power, don’t forget to factor in the efficiency (you are given the factory PF). You have power and pf so you can calculate VARS and VA.


You now have a description for when the motor is and isn’t attached, so you can draw a third triangle that describes the motor (using the difference in KW & KVARs ) from that you can see the motor PF and KVA.

Hope that makes sense, if not let me know and I’ll try again,,

Bob
:D
 

eng.saeed said:
Hi everybody....

I have a problem that I could not solve, and really need a help...

It says:

In a factory, the following are the loads:

Induction motors: 1000 hp
0.7 average power factor
0.85 average efficiency

Lighting and heating load: 100 KW

A 3Φ synchronous motor is installed to provide 300 hp to a new process. The synchronous motor operates at 92% efficiency. Determine the KVA rating of the synchronous motor if the overall factory power factor is to be raised to 0.95.
Determine the power factor of the synchronous motor..



Thanx a lot



hmm, seems a 'simpe' school problem ???

Ok...




1000 hp = 1000 * 0.736 Watt = 736 kW mechanical power

(1 european horse power = 736 Watt)


736 kW / 0.85 = 865.9 kW = electrical power to make 1000 hp

power factor cos(fi) = 0.7

fi = acos(0.7) = 45.54 degree

P = 865.9 kW
S = P / cos(fi) = 865.9 kW / 0.7 = 1237 kVA
Q = S * sin(fi) = 1237 kVA * 0.71 = 883.4 kVAr

Light and heat draw 1000 kW with powerfactor of 1

we cannot add 1237 kVA and 1000 kW directly for 2237 kVA (wrong answer) , but we can add real part (P) and imaginary part (Q) separatly, give:

P = 865.9 kW + 1000 kW = 1865.9 kW
Q = 883.4 kVAr + 0 = 883.4 kVAr

and from this calculate new KVA value S

S =sqrt( P^2 + Q^2) = sqrt(1865.9^2 + 833.4^2) = 2043.5 kVA

and power factor:

cos(fi) = P/'S' = 1865.9 / 2043.5 = 0.91 (or 25.3 degree phase angle)

---

new syncron machine load give:

300 hp * 0.736 = 220 kW

92% effency = 220 kW / 0.92 = 239.1 kW

overall power factor is given 0.95 and old power factor calculated before is a 0.91.

we know from old factory load

S = 2043.5 kVA
P = 1865.9 kW
Q = 833.4 KVAr


we add old P above with new motor load:

Ptot = 1865.9 kW + 239.1 kW = 2105 kW

we also know new overall power factor as cos(fi) = 0.95

and 'S' with new power factor and know Ptot give

Stot = Ptot / cos(fi) = 2105 kW / 0.95 = 2215.8 kVA

calculate phase angle:

fi = acos(0.95) = 18.2 degree

sin(fi) = sin(18.2) = 0.312

and

Qtot = Stot * sin(fi) = Stot * 0.312 = 2215.8 kVA * 0.312 = 691.8 kVAr

old load have Q = 883.4 kVAr and total Qtot have now 691.8 kVAr

new machine give Qm = Qtot - Q = 691.8 - 883.4 kVAr = -191.5 kVAr (capacitive reactive load - it's possible to make with syncron machine!)

new syncron machine:

P = 239.1 kW
Q = -191.5 kVAr
S = sqrt(239.1^2 + -191.5^2) = 306.3 kVA
power factor cos(fi) = P/S = 239.1/306.3 = 0.78
phase angle -38.7 degree ie. capacitive load

factory before new motors:

P = 1.865.9 kW
Q = 882.4 kVAr
S = 2043.5 kVA
cos(fi) = 0.91
phase angle = 25.3 degree (inductive load)

factory after new motor

P = 2105 kW