Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

IP3 Measurement,need help

Status
Not open for further replies.

kmmaran

Member level 1
Joined
May 16, 2005
Messages
41
Helped
2
Reputation
4
Reaction score
2
Trophy points
1,288
Activity points
1,596
ip3 measurement

Need some help on IP3 measurement, actually two signal generators is used to measure IP3, lets say I am measuring IF Amp, and my IF is 73.35MHz, what is the frequency supposed to set for this two signal generators. (My radio is working on 800MHz).

Thank you
 

how to measure ip3

I think it is about the BW of you baseband signal. If you channel is 30 kHz , it should be about 30 KHz.
 

measure ip3

The frequency separation of the two input carriers shall be selected so that the 3rd order IM products lies within the passband as well.

In the case of a 30 kHz BW, use a maximum of 10 kHz frequency separation. At 10 kHz frequency separation, the measured IM products will have a frequency separation of 30 kHz, which will exactly fit within the 30 kHz BW.
 

how to measure iip3

I think within the BW, select the frequency separation as small as possiable, two large will make the measurment not accuracy, maybe 5 K is suitable
 

how to measure the ip3

Usually, IP3 performances of an amplifier (or in general of an apparatus) change very little with frequency.

So it's not the channel separation that should set the frequency separation but the knowing that you are into the bandwith of your apparatus. Frequencies should be far enough to be seen cleany (small phase noise) into Spectrum Analizer but closer enough to see 3rd Order and 5th order into the BW and into the SA screen.

A note about power level required.
To be sure enough that the 3rd Order will be seen far enough from noise but the signal still remain in linear region, as rule of thumb, is to tune the level to see
the 3rd Order 40 dB smaller than test signal.

A note about accuracy.
IP3 measurement give not a number, give a band of acceptance. Looking for high accuracy is not required and make a non sense.
 
  • Like
Reactions: banner

    banner

    Points: 2
    Helpful Answer Positive Rating