Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

[SOLVED] Crystal Load Capacitor

Status
Not open for further replies.

abhishek.2138

Full Member level 2
Joined
Dec 21, 2013
Messages
131
Helped
0
Reputation
0
Reaction score
1
Trophy points
1,298
Activity points
2,383
For microcontroller crystal oscillator, as in below snap.
1676716671799.png


To calculate the load capacitance following formula is used -

1676716760076.png

where, Cs = PCB stray capacitance.

Now, here are Cx1 & Cx2 in series with each other? If they are in parallel, it will be Cx1 + Cx2.
Can anyone pls let me know about Cx1, Cx2 series combination & HOW they are in series ?
 

Hi,

the loop of the resonance circuit is: GND --> CX1 --> XTAL --> CX2 --> GND

Cs is PCB stray capacitance + input capacitance of XTAL1

There are plenty of application notes around explaining the circuit. I guess every XTAL maunfacturer provides them for free and with very good quality. (Because they want to sell their XTALs)

Klaus
 