Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

HFFS and Impedance Measurement

Status
Not open for further replies.

Buqpa

Member level 2
Joined
Oct 31, 2004
Messages
50
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,286
Activity points
453
I've been trying to measure the impadance in a CPW line using HFSS. Inout impadance is quite accurate but output impdance deppends on line length!!! I think this is not true.

I've been desing the waveports (in & out) using HFSS specifications and the impdance measurement i'm using is the Zo parameter at Matrix Data

Any idea???
THanks a lot!
 

Buqpa said:
I've been trying to measure the impadance in a CPW line using HFSS. Inout impadance is quite accurate but output impdance deppends on line length!!! I think this is not true.

I've been desing the waveports (in & out) using HFSS specifications and the impdance measurement i'm using is the Zo parameter at Matrix Data

Any idea???
THanks a lot!

Try to use Zpv for CPW structure. Increase the accuracy of the port to e.g. 0.1%.
The rule of thumb in defining the waveport size is quite flexible. Try to see to field magnitude at the port after simulation. If the difference between the highest and the lowest value is large (e.g. 1e3), you may reduce the port size to get more accurate result.

wlcsp
 

    Buqpa

    Points: 2
    Helpful Answer Positive Rating
Thanks a lot! I will try it and tell if it worked
 