Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Junction temperature and heatsink

Status
Not open for further replies.

18F4520

Junior Member level 1
Joined
Jan 29, 2014
Messages
15
Helped
0
Reputation
0
Reaction score
0
Trophy points
1
Activity points
82
My TRIAC datasheet says Tj max = 125C but should i really calculate my heatsink for that temperature, or use lower?
 

Hi

You should take some margin. This is definitely better in order not to have surprises.

I would recommend to calculate your heasink to a temperature between 100°C and 110°C
 
Tj max will specify the max junction temp, the device can withstand ... you have to look into the graphs in DS to see what's the allowed rms current at this Tj. That means you may not be able run at max power what you need at this temp of junction. Also, with or without heat sink, you can calculate what can be the ambient temp for the device operation. This is more important from the product function point of view.
 
Also allow for dust and fluff on the heat sink, that the life of a semiconductor is doubled for every 10 degrees C BELOW Tj max and you don't want people to burn them selves on the heat sink.
Frank
 
I calculated heatsink for 500W(2.27A) load to be max 20 K/W (Tj max = 125C Ta=50)

screenshot_282.png


Now this graph confuses me, because it shows maximum mounting base temperature for different loads.
screenshot_278.png
 

hi

Are you sure you want to have a temperature coefficient of 20 Kelvin per watt, if you have a 500W load?
 

I calculated heatsink for 500W(2.27A) load to be max 20 K/W (Tj max = 125C Ta=50)

As mentioned earlier, the power handling capacity for the triac at max junction temp will not be higher. It will be very less. Share the triac part DS so that we can look into the P vs jn temp graph. This can suggest what can be the max jn temp for handling 500W power.

Just for example, if for 500W power dissipation, the allowed max jn temp is 110C, then you have work backwards from here for heat sink Rth calculation. Take a safety margin for device jn operation and also for the heat sink Rth.
 

TRIAC DS: **broken link removed**

An i used this as a guide **broken link removed**
 

Hi,


500W is the power of the load. It has nothing to do with the heatsink nor with the power dissipation of the triac.


Power dissipation of the triac is max 3W (@ 2.27A RMS and 180°).

So a 20K/W (junction to ambient) heatsink causes a 60K temperature rise. If the max junction temp is 125°C then the max ambient temp is about 65°C.

******
The picture in post #5 is the safe operation area with tespect to load current and ambient temperature. Also knowns as derating curve.

Klaus
 

Power dissipation of the triac is max 3W (@ 2.27A RMS and 180°).

So a 20K/W (junction to ambient) heatsink causes a 60K temperature rise. If the max junction temp is 125°C then the max ambient temp is about 65°C.

Actually, 20K/W is heatsink to ambient, add 3K/W for junction to case and 1.4K/W case to heatsink, and you will have 24.4K/W junction to ambient.
24.4C/W*3.07W = 75°C rise.
If maximum junction temperature is 125°C, then maximum ambient temperature is 125-75=50°C.
 

Perfectly calculated.

Klaus
 

According to datasheet, but i was looking for some practical advises.
 

Status
Not open for further replies.

Similar threads

Part and Inventory Search

Welcome to EDABoard.com

Sponsor

Back
Top