Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

[SOLVED] DftAdvisor scan issues.

Status
Not open for further replies.

Andrei Salahoru

Newbie level 5
Joined
Jan 19, 2015
Messages
10
Helped
0
Reputation
0
Reaction score
0
Trophy points
1
Activity points
81
Hello, guys.

First of all, I am thankfull to be part of this forum.

Now, I have this problem when I am trying to run DftAdvisor for 68HC08 top file. It says that "
Warning : There are 122 S1 violations ( unstable nonscan cells when clocks off ).
122 non-scan memory elements identified as non-scannable.
...
Error : There were 2 S6 violations ( drive scan-in pin of a sub chain or pf a scan cell in unspecified scan chain). "

I am using a script for DftAdvisor.
 

Hello Andrei,

Have you done analysis to solve violations?
Are these violation causes and simulation mismatch or you just want to solve it?

--
Thanks & Regards,
Maulin Sheth
 
Hi, Maulin.

Fortunally, I figured out how to solve that problem and I would like to apologise because I didn't post here.

I had to exclude DFS1 gate from design with Leonardo Spectrum tool. After I did this, everything was fine.

Thank you for your time.

Best regards,
Andrei Salahoru
 