Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

stability problem of condtional amplifier?

Status
Not open for further replies.

abdoeng

Advanced Member level 2
Joined
Feb 22, 2004
Messages
647
Helped
76
Reputation
152
Reaction score
63
Trophy points
1,308
Activity points
3,810
hi all,i add resistor at drain of ATF36077 to make k>1 in all band(8-12 GHZ) but the stability still < 1 .any method to make stabilty >1
regards
 

there are two kinds of unstability:(1)the rf unstability(2)the feed DC power unstability:
the resistor in the drain only conquer the feed DC unstability,but not RF unstability,try to add a resistor in the rf chain
 

    abdoeng

    Points: 2
    Helpful Answer Positive Rating
I used a similar device a while ago and the problem was stability at lower frequencies. To overcome this, add a resistor in series with gate, bypassed by a capacitor at your amplifier frequency. Should help!

Instability not necessarily occurs in your band of intest. It can occur everywhere!
 

There are several ways to stabilize the transistor:
1. add a series resistor at the gate.
2. add a parallel resistor at the gate
3. series resistor at drain
4. parallel resistor at drain
5. a feedback (drain to gate) resistor with capacitor.

and more
 