Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by SIVAPRAKASHTRIDENT

  1. S

    [PIC] Lcd 16*2 displays garbbled vales after long time usage

    1% of the boards are having the problem it senses the temperature of the device and controls the motor for the set values. The LCD display characters are stored in const char and called when it needed. Its difficult for change the controller IC(Any way thanks for the suggestion) If you could...
  2. S

    [PIC] Lcd 16*2 displays garbbled vales after long time usage

    Hi, All characters are getting garbled. Don't have a reset switch for resetting the controller or no program reset is given in code for lcd after power down for a minute it works properly. No i haven't test the whole product for emc. yes all the other components working properly except the...
  3. S

    [PIC] Lcd 16*2 displays garbbled vales after long time usage

    the Device is doing the same operation for 8 moths . I have a doubt will the memory overflow arose after that much working hours. hex file and schematic are attached for your ref
  4. S

    [PIC] Lcd 16*2 displays garbbled vales after long time usage

    The compiler used in this is HITECH C. code is written in C.
  5. S

    [PIC] Lcd 16*2 displays garbbled vales after long time usage

    Easyrider83 it also worked for me well for 8 months. Suddenly i got the noise issue. once i power off the whole circuit for sometime. it worked properly again. I want to know what could be the reason..
  6. S

    [PIC] Lcd 16*2 displays garbbled vales after long time usage

    I am using a 16*2 LCD display for my design. It works fine initially during long run it displays wrong characters. controller works fine for the other operations i have use PIC16f876 controller. LCD lampex 16200 Anyone help me to resolve this issue
  7. S

    Smps components failures (tny, capacitor, resistor)

    Smps componets failures (tny,capacitor,resistor) Hi Everyone, Have a great day. I am using a SMPS WITH min voltage of 110 V nominal voltage 230 V and Max voltage 265V. This SMPS having failure of TNY CAPACITOR AND RESISTOR. The Sch is attached with this ( RED marked components are failing...
  8. S

    Triac problem while switching an inductive load

    Hi, Will the the clamping voltage destroy the Triac.
  9. S

    Triac problem while switching an inductive load

    Hi, Yes it is operating in the 1 and 4 quadrants. i am working with an AC load.
  10. S

    Triac problem while switching an inductive load

    Hi, Is there any chance of triac internal short due to increased junction temperature.
  11. S

    Triac problem while switching an inductive load

    I am using a posive gate pulse. So it would work in 3+ and 1+ quadrant. Is there any way to find the dv/dt of an load. I am using a inductive load. But the when triac fails the terminals are shorted inside. What could be the reason for the triac internal short. I have searched in net every...
  12. S

    Triac problem while switching an inductive load

    Hi , Thanks for the reply is there any other triac which will be suitable for this application
  13. S

    Triac problem while switching an inductive load

    Hi, Yes i am sure the load is 8 mA. I have measure it. The L value of inductive load is 1.5 H. I am using a timer IC 4541 for giving the pulse.
  14. S

    Triac problem while switching an inductive load

    Hi, dv/dt > 500 V Insulation voltage 1500 Vrms Igt 10 mA di/dt 50 A/us IH 10 mA
  15. S

    Triac problem while switching an inductive load

    Hi, When triac is "always on". the gate mt1 and mt2 are internally shorted. if i replace the triac it works fine.