Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
You could use the multiplexer , and use the micro to average them.
Or you could feed the signal levels into a summing amplifier and then divide the output back down again to get the average without any computing.
Use an opto triac.
An opto triac will 'hard fire' the main triac. ( Edit - this applies to Triacs. I've not used it with Thyristors but I suspect the following still applies ).
A hard fire means that the triac gate is ALWAYS being driven when required to be on.
Soft trigger is the transformer...