Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Well there are several which can be accessed in Virtuoso layout menus
(1) Diva
(2) Dracula
(3) Assura
Only (1) and (2) comes packaged with IC5033. (3) is in a separate software package and needs to be installed separately. Once (3) is installed and the path variables setup correctly, it can...
assura has not been installed in this hierarchy
Hi the method for doing this is in the Cadence Installation document included with Assura.
Look at chapters2and 3 for the details of setting up the correct variables so that you get the Assura menu in the Virtuoso Layout menu
Assura3.0 file is 354MB size for linux. IC5033 doesn't include Assura.
Assura is a separate package and can be ran independent of IC5033. Just use the command avview after installing Assura.