Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by Nassou

  1. N

    ADC question- input voltage range and its sampling frequency

    ADC question Hi Gents, I have a question that might appear stupid to you experts.... Is there any relationship between ADC input voltage range and its sampling frequency? Could you please advice some references? Thanks. Nass
  2. N

    Some questions about "image problem."

    hi a1919kimo, IM stands for image (here at 800MHz), which folds into 900MHz-800MHz=100MHz after donwconversion. Hope it clarifies. Nass
  3. N

    Some questions about "image problem."

    Hi a1919kimo, Image problem is linked to mixer. In your case, I assume your IF=100MHz (RF-LO), the image will be at IM=800MHz folding in the same band than the wanted signal after downconversion (LO-IM). To remove the image your have to filter before the downconverter mixer. Hope it helps. Nass