Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
I was double check it and it didn't matter. At this test input power level (from signal generator) is -20dBm and use an attenuator in exactly SG output and with a cable connected to SAW1. So -40dBm achieve to SAW1 and SAW1 connected with thru SMA to SAW2 and SAW2 connected with cable to SA. The...
How to test it to avoid leakage? Due to Stopband attenuation (about 60~70dB each one) and SA noisefloor level (about 130~140dB) limit and etc.
I change the cable, put all screw, kept power on and disconnect DUT, even add an attenuator, But it didn't matter.
17dBm comes from signal generator.
SAW1:https://ibb.co/SPMVymJ
SAW2:https://ibb.co/2qdP7HM
Together: https://ibb.co/prX4r6p
(Center frequency (95.38MHz) is in stop band region)
input level 17dBm, and after insertion loss is about 0dBm.
SA picture: https://ibb.co/ZJ8Fvcz
ok, got it. Each of them is a module with case and connected with male thru SMA.
- - - Updated - - -
- - - Updated - - -
In first I thought it was leakage, so I put distance between them about 1...
Hi
When I series two SAW filter, why the attenuation less than sum both of them in stop band region. Each of them (in stop band) have 60dB attenuation but when series them, the attenuation is equal to 85dB.
What happening? Why didn't reach to 120dB?
Then, I put a 20dB attenuation between...
1- I can't take a picture. The antenna (RX and TX) installed on tower and have 5m distance between them and the cable length is about 20m and then connect to Device.
2- Yes, Both of them in same PCB.
3- UHF band with narrow bandwidth. and antenna type is omni like as "Laird Technologies FRX450...
Hello
In my system, when the PA (TX chain) is On, the noise floor increase about 10dB and influence (and coupling) in RX chain (RX Sensitivity).
Is there a way to reduce PA noise floor
regards.