Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
If I have a CPWG of length 1mm which gives IL of say X dB, then what would be the IL for 2mm of same CPWG. Should it not be 2X dB.
I did simulation in HFSS(Driven terminal) for 2mm and 5mm of CPWG and following are the results:
Length Zo IL IL/cm RL
2mm 49.909 -0.4436 -2.218 -25.9589
5 mm...