Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by jagadeeshvulava

  1. J

    is it possible to use one SPI for interfacing two devices with different CSN & CEpins

    Re: is it possible to use one SPI for interfacing two devices with different CSN & CE ThanQ Sivamani.... Now I'm trying to initialize the SPI and interfacing them...... One more thing ... is there any sample codes available for nRF24L01 RF transceiver ........ i need samples for...
  2. J

    is it possible to use one SPI for interfacing two devices with different CSN & CEpins

    is it possible to use one SPI for interfacing two devices with different CSN & CEpins Hi.. I'm working on NRF24l01 wireless transivers... i need to interface two transivers to stm32f103 demo board... there i have only one SPI to interface .... Is it possible for me to interface transmitter and...
  3. J

    [SOLVED] need lib files of ATMEL CONTROLLERS... for OrCAD9.1 (Ex: atmega8, 16, 32 controllers)

    Sorry I'm unable to get any data from that link .... still I'm unable to download/get library files.............
  4. J

    [SOLVED] need lib files of ATMEL CONTROLLERS... for OrCAD9.1 (Ex: atmega8, 16, 32 controllers)

    yes yes....for TQFP32 and TQFP44... by mistaken I've typed like that.. sorry...
  5. J

    [SOLVED] need lib files of ATMEL CONTROLLERS... for OrCAD9.1 (Ex: atmega8, 16, 32 controllers)

    HI all, i'm trying to design one schematic with atmega8 (TQFT) controller.. i need OrCAD library file for that controller... please help me to get those lib files... thanQ in advance
  6. J

    ADC channel monitoring for ATMEGA8

    here i'm going to use 8bit adc only....
  7. J

    can i connect 3 sensors to atmel at89s52....?

    hi what type of sensors you are going to use on this... you have 8-channel ADC is there and more number of free pin on controllers... so you can use this one....
  8. J

    ADC channel monitoring for ATMEGA8

    Hi all, I'm trying to monitor the voltage range between 0 to 5V.... On ADC channels of ATmega8 controller.. please give reference ADC values for those voltages .... thanQ
  9. J

    Embedded linux Video Training tutorials for beginers

    Hi babar... I suggest you to look into these videos for the basics.. https://www.youtube.com/user/linuxkernellearning?feature=g-high-u here is the link... - - - Updated - - - Hi babar... I suggest you to look into these videos for the basics...
  10. J

    sim900 ftp error issue...

    Hi all, I'm working on SIM900 module to upload data to server , i'm using AT command set to upload data through GSM modem... when i"m trying to upload data through termnal manually it's working fine.... when i'm trying to use the same procedure and flow to develep a firm ware(for STM32...
  11. J

    gsm module(sim900a) not working

    HI all I've worked hard on SIM900.... how ever its working fine now .... the problem is when i'm sending commands to the module with some delay... but i'm not reading their response from the modem ........ now i'm sending command and wait for the response .....All commands are working fine...
  12. J

    [SOLVED] enternal interrupt configuration for STM32F103VCT6 PROCESSOR

    I've read this document but still confusion is there....... is there any reference code is there..........??? thank you ,,,,,
  13. J

    [SOLVED] enternal interrupt configuration for STM32F103VCT6 PROCESSOR

    HI all, I'm new one to ARM processors..... I'm using stm32f103 processor for an embedded application.. i need to configure one IO pin in interrupt mode... can any one help me to interface this to an external button on the board.. which register to be set to enable interrupts.... and how to...
  14. J

    GSM modem Profile settings....

    HI all i have to different sim300 modems..... when i run the command "AT&V" their response is different in some portion ...... first modem response : +CLCAL: 1 +CCPD: 1 +CMTE: 1 second modem response: +CCPD: 1 +CMTE: 0 +CNLP: 2,0 +PSP: 0,15 while i'm trying to send SMSs to all contacts...
  15. J

    gsm module(sim900a) not working

    HI, i've configured sim300 with micon and it is working properly for sending sms and generating call to other mobiles........ here your are initiating call and next to that disconnecting(terminating) the initiated path......... we need to wait untill call is initiated mean it ring on other...