Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
You are right. The optimum source impedance for minimum NF may not match the input impedance of a LNA. You have to trade-off RL for NF. Because you are designing a LAN, NF should be more important. Keep the RL within the spec and the lower NF you can get the better. Thanks.
citifile to touchstone
You are right, assuming you have a good 100Ohm load directly attached to the output port. For a two-port network, you may get S11 or S22 data by switching port1 and por2 , but how can you get the insertion loss in reference to 100Ohm?
touchstone insertion loss calculation in excel
In 1-port measurement, you can do that. However, with 2-port measurement, the measured S11 in 50Ohm system is affected by the load on port2.
For a certain network, a unique Z, Y, or T matrix can be used to fully describe the network. While the...
agilent smith chart tools
Go to the website of ansoft, and download the student version of serenade. There is a useful Smith tool in it.