Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Dear,
There is no need for Ground Plane for an SRR.
SRR in principle working in magnetic field , and it show some inductance , while the capacitance is formulated between the gap edge.
best regards
magnetic electric wall
thank you for the answer, still some misunderstanding stuff!!
If I have at the same time electric and magnetic wall should they be perpendicular to each other ? and this apply only for 1 mode ?
on the other hand what you mean by symmetric wall ?
thanks in advance
electric wall and magnetic wall
on what basis the Electric wall and the magnetic wall are selected in a structure?
Is that based on experience or on the field distribution on the structure before solving it ?
Declare if there is some reference based on that ...
thanks in advance
Yes , it used like that in order to compensate for frequency shift..
after you use the tapped coaxial input it could be the frequency will shift a little bit and in order to compensate you change the resonator lenght..
Dear ..thank you for your reply , actually I try to simplify the problem to 3 conductor equally spaced and has a same height h , but the real case is 5 conductors spaced s1,s2,..s5 and the height is h1,h2,h3..,h5 respectively.
Also what I expect that the problem should be reciprocal i.e the...
In order to calculate the impedance , first u need a ground reference , try to draw another air cube containing your conductor cube , and assign pec to one side of the air box as reference ground while keeping the other 3 like RAD of Perfect H boundary , the other 2 opposite side of the cube...
Dear
I have to simulate a multi conductor structure formed from 3 parallel wires for calculating the Modal characteristic impedance Z0.
The wire has the dimension w, spaced by s , and has a thickness t , and a height h over a one common ground plate ( conductor number 4).
I starting by assigning...
Re: 2D EM software
Dear
Try to use Ansoft 2D extractor.
This tool give you what u need R,L,G,c Z0,..:Lumped , distributed circuit for transmission line or any complex geometry, also u can have multiple format output like spice, maxwell,..
Enjoy
Ok..I read an Ieee about measuring TL cap , and I try the method in the lab, the method will give good agrement till 1 Ghz , if u measure the capacitance
via the Rdc, also Rdc must be measured using the 4-point method.
On the other hand u must keep in mind that HFSS will give u a non trusted...
Thank you for your reply
I would like to tell you that this procdure is used for 1D plot and using the cartesian coordinate , and my question is how to plot 3D farfield[b] parametrized ..
In any case thank you again for your help..
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.