Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Hi all,
In OOo 1.1.5, how to set the default template? I see that in the OOo's help, it says the procedure is "file->templates->orgnize-> double click 'default' folder -> right click the template-> choose 'set as default template' command".
But for me, there is no such a command called "set as...
Cadence AMS help document says that APS is supported. But now in ADE->Simulation->solver, there are only 2 options, spectre and ultrasim. I don't know what's wrong. Can anyone give me some advice?
I'm using IC5141 USR6 + MMSIM 7.2 + IUS 8.2.
I think you can. But be careful about:
1) If it's a level-up shifter(say, 2.5V -> 3.3V), you need to increase the w/l of NMOS, and decrease the w/l of PMOS, in order to achieve an equalizatioin of rising time and falling time.
2) If it's a level-down shifter(say, 3.3V -> 2.5V), you need to tie...
Hi,
As we all know, the analog simulator is typically spectre or ultrasim in Cadence AMS Designer. However, the ultrasim is precision-limited and spectre is much slower (well, spectre with turbo mode is indeed faster but not fast enough if having a large scale of circuit).
So I want to know...
ncelab: *f,interr: internal error
I'm not sure what's the exactly reason for this, just share my experience.
suppose you have 2 lib files with the same name, say, libgcc.so.1, one is provided by linux system distribution, the other is provided by EDA tool you installed. So the path for them...
spectre jitter peak to peak
do pss and pnoise analysis.
in pnoise setting page, select "jitter" for noise type.
the result can be seen in direct plot -> main form.
cscope has 2 options relating to this problem:
eg,
#>cscope -pfiles pfile -script script_file
-pfiles means to plot a figure at start-ups.
-script means load a script at start-ups.
you may check if your cscope is launched with such options.
Re: Help me.....
in low freqency, smaller parasitic capacitance will not cause problem. but if you are dealing with RF circuit, impedance matching is crucial. so you should be very careful to adjust the capacitance.
Re: opAmp output stage
well, that is a bit strange.
1. you could observe the triodes' states while sweeping v2. are they in amplifing region all the time?
2. maybe 10uA is too small. if R_out is 200ohm, and you want a +2V output, then for the npn-output-triode, I_ce = 10mA. assume beta =...
I find that there are also many non-bandgap reference papers which achive fairly low temperature coefficient. So what is the main consideration for the industry to doubt non-bandgap structure? Does non-bandgap have universal weak points? Is it more deviation caused by PVT or worse psrr or...
hello,
any one know that the bandgap ref and non-bandgap ref, which is used more commonly in industry?
if the bandgap is more common (this is my vague impression, i'm not sure indeed), are there any general drawbacks which are difficult to overcome for the non-bandgap ?
thanks.