Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by dsanthosh67

  1. D

    How to test instrument leak voltage

    Thanks for your valuable information..pls explain from which two points I need to measure the insulation resistance? Earth continuity is between earth pin in power socket to the instrument case right?
  2. D

    How to test instrument leak voltage

    As per instructions our instrument surely meets in CLASS I. If I disconnected the protective earth and measure what will be the average voltage between the body to earth. When i measure in this case different multimeter will shows different voltage.Pls refer the attached image in previous...
  3. D

    How to test instrument leak voltage

    Pls find the attached image for your reference. Which I have tested in two different multimeter..Here I have noted eractic values which is right or wrong?. I'm looking to ensure the instrument does not generate any leak voltage or shock free instrument..
  4. D

    How to test instrument leak voltage

    Hi all, Actually I have an instrument to detect component failure. Which is operated at 230V AC @50HZ. Instrument properly connected earth..when I test earth to neutral voltage it's around 3V AC.. Kindly suggest me how to test the instrument leak voltage.. Is it right way to test the voltage...
  5. D

    lic_error Lmf-02096' error?

    Hi all, Recently in my new PC installed Orcad 16, Installation completed successfully but not able to open the software. I got the below error " lic_error Lmf-02096' error?" kindly suggest me to solve the issue.
  6. D

    Detect Reverse Polarity of Coil

    Hi All, I have a coil, it will have the resistance of 1.5Ω. Assume, if the coil is winded 10 turns with clockwise or anti clockwise it will have the same resistance but is it possible to detect it is winded in clockwise or anti clockwise.
  7. D

    Need help to identify this component

    Thanks for your response, Its came under in power supply from china Kindly share us any data regarding this.
  8. D

    Need help to identify this component

    Hi All, I'm looking for this component to replace, It looks like a signal conditioner but i'm not able to get any details about this. Please suggest me where this component available to buy or any other equivalent to replace.
  9. D

    How to protect for Surge Voltage and Current in DC

    Thanks for your suggestion, I will try that surely. I have an alternate idea too please comment about that how much it will helpful to me. It was connecting ground terminal with the earth, I don't know exactly how it will work. Awaiting for your valuable feedback's..
  10. D

    How to protect for Surge Voltage and Current in DC

    Working environment of the device is welding industry through stabilizer, MCB finally from the SMPS getting power to this device.
  11. D

    How to protect for Surge Voltage and Current in DC

    Hi, Worst condition Maximum Input Voltage at VB is 28V DC but normal operating voltage is 24V DC. This too also works fine more than 5lakh cycles suddenly got damaged due to the unexpected reason. I'm not able to find the exact reason for broken that diode(TPSMC47A). Is there any way to protect...
  12. D

    How to protect for Surge Voltage and Current in DC

    Dear All, I'm facing a issue in the below attached circuit, Here the diode D200 a TVS Diode was broken frequently i don't know the exact reason but it may broken due to any surge voltage. Please suggest me to solve the issue. Regards, Kumar.
  13. D

    Orcad layout file not able to open

    Hi all, I'm using orcad16.0, .DSN, .GTD files are opening but .MAX file are not able to open, Kindly suggest me a solution to solve this issue. Regards, Santhoshkumar
  14. D

    Suggest a 24V Relay to Switch 1500VAC

    Thanks you all for your valuable Feedback, Is there any other options to switch this voltage? As per my application there is a two source voltage(500VAC & 1000VAC) Sometimes it may go to 1500VAC depends upon the variant but its rare to use. For my condition, at a time one voltage only in ON...
  15. D

    Suggest a 24V Relay to Switch 1500VAC

    Coil Voltage = 24VDC, Switching Voltage = 1500VAC Load Current = 50mA, I need a relay with a contact capacity to carry 1500VAC..